Setup & Care Guide

Setup & Care Guide

Getting started with PEMA

PEMA is a direct-connected countertop reverse osmosis system — no tank, no refilling. Here's what you need to know to set it up, use it daily, and keep it running well.

Before you begin

  • Water line: requires a compatible drinking-water inlet.
  • Drain: a separate RO wastewater drain connection is required.
  • Power: 110-120V AC outlet.
  • Clearance: leave at least 10 cm (4 in) open space on each side for airflow.

Hot water can dispense at up to 212°F (100°C) — keep hands and children away from the nozzle during a hot pour.

Installation overview

PEMA installation diagram: water supply to PEMA unit to RO drain

PEMA connects between your under-sink cold water supply and a dedicated RO drain line. Professional installation is included for the Founding 100 — your installer will complete the connection, check for leaks, and perform the required first-use flush before you drink the water.

Controls at a glance

PEMA control panel labeled diagram

Select Hot, Tea, Warm, Cold or Volume, then press the center Dispense button to pour. The Child Lock is on by default and restricts the heated modes — tap it to unlock before selecting Hot, Tea or Warm.

Your two-stage filter system

PEMA uses two replaceable filter cartridges:

  • Stage 1 — Pre-Filter (right slot): sediment & carbon composite. Replace after 210 days or 2,100 L (554 gal), whichever comes first.
  • Stage 2 — RO Membrane (left slot): reverse osmosis membrane + post-activated carbon, reduces TDS by up to 95%. Replace after 360 days or 3,000 L (792 gal), whichever comes first.

When the Filter indicator flashes red, a cartridge has reached its service-life limit.

Replacing your filters

PEMA filter replacement 6-step guide
  1. Close the water supply. Turn off the isolation valve located under the sink.
  2. Release residual water. Press the room-temperature or Cold water button to drain water remaining in the line.
  3. Remove the old cartridge. Access the filter compartment and twist the cartridge to unlock it.
  4. Fit the new cartridge. Twist inward to lock: RO Membrane on the left, Pre-Filter on the right.
  5. Restore supply and reset. Reopen the isolation valve, check for leaks, then press and hold the Filter button to reset the filter-life counter.
  6. Flush before drinking. Dispense and discard 3 liters (about 101 US fl oz) of water before drinking.